{"id":525,"date":"2024-03-06T08:38:00","date_gmt":"2024-03-06T08:38:00","guid":{"rendered":"http:\/\/gn-desander-desilter.com\/?p=525"},"modified":"2024-03-29T13:35:58","modified_gmt":"2024-03-29T13:35:58","slug":"brief-introduction-to-motor-mounting-type","status":"publish","type":"post","link":"http:\/\/gn-desander-desilter.com\/index.php\/2024\/03\/06\/brief-introduction-to-motor-mounting-type\/","title":{"rendered":"Brief introduction to motor mounting type"},"content":{"rendered":"<p><strong><em>The<\/em> <\/strong>way an electric motor is mounted (see diagram below) refers to how it is connected to the frame or other components in a mechanical system. There are two code forms, one is IMBx and the other is IMVy. Among them, IM is the internationally accepted installation method code; B represents horizontal type, which is limited to the motor axis being horizontal; V represents vertical type, which is limited to the motor axis being vertical; x and y are each 1 to 2 numbers, indicating the connection location and direction.<\/p>\n<p><!--more--><\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-524\" src=\"http:\/\/gn-desander-desilter.com\/wp-content\/uploads\/2024\/03\/\u7535\u673a\u56fe-300x292.jpeg\" alt=\"\" width=\"300\" height=\"292\" \/><\/p>\n<p>Motor installation type code<\/p>\n<p>IM+B (or V)+Arabic numerals (1-2 digits)<\/p>\n<p>IM: The abbreviation of &#8220;Installation al Mounting type&#8221; in English;<\/p>\n<p>B: Indicates that the motor is installed horizontally when in use, with the shaft in the horizontal direction;<\/p>\n<p>V: Indicates that the motor is installed vertically when in use, with the axis perpendicular to the horizontal direction.<\/p>\n<p>Note: The main shaft extension end of the motor is uniformly defined as the &#8220;D&#8221; end. If it is a double-shaft extension motor, the auxiliary shaft extension end is uniformly defined as the &#8220;N&#8221; end.<\/p>\n<p><img loading=\"lazy\" decoding=\"async\" class=\"alignnone size-medium wp-image-523\" src=\"http:\/\/gn-desander-desilter.com\/wp-content\/uploads\/2024\/03\/GB997\u548cIEC60034-7\u5b89\u88c5\u65b9\u5f0f\u5bf9\u6bd4-224x300.jpeg\" alt=\"\" width=\"224\" height=\"300\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>IMB installation code explanation<\/p>\n<p>B3\u2014\u2014Horizontal type installed on foundation components with footings;<\/p>\n<p>B35\u2014\u2014Horizontal borrowed foot is installed on the basic component, and is attached with flange installation;<\/p>\n<p>B5\u2014\u2014Horizontal flange installation;<\/p>\n<p>B6 &#8211; horizontal type installed on the wall with feet, the feet are on the left when viewed from the D end;<\/p>\n<p>B7 &#8211; horizontal type installed on the wall with feet, the feet are on the right when viewed from the D end;<\/p>\n<p>B8 &#8211; Horizontal type installed on the top with feet;<\/p>\n<p>B9\u2014\u2014Horizontal D-end without end cover is installed on the end face of the D-end machine base;<\/p>\n<p>B15\u2014\u2014The horizontal type adopts the main installation on the foundation, and the D-end without end cover adopts the auxiliary installation on the end of the machine base;<\/p>\n<p>B20\u2014\u2014Horizontal type has raised feet and is installed on the basic components with the feet.<\/p>\n<p>Rule: There are no auxiliary or additional installations with only one numerical code.<\/p>\n<p>IMV installation code explanation<\/p>\n<p>V1\u2014\u2014Vertical installation with flange, D end facing down;<\/p>\n<p>V15 &#8211; vertical installation on the wall with feet and flange for additional installation, with the D end facing downward;<\/p>\n<p>V3 &#8211; Vertical installation with flange, D end facing up;<\/p>\n<p>V5\u2014\u2014Vertical installation on the wall with feet, D end facing down;<\/p>\n<p>V6 &#8211; vertical installation on the wall with feet, D end facing up;<\/p>\n<p>V8\u2014\u2014Vertical D-end without end cover, installed on the end face of D-end machine base, with D-end facing down;<\/p>\n<p>V9\u2014\u2014Vertical D-end without end cover, installed on the end face of D-end machine base, with D-end facing up;<\/p>\n<p>V10 &#8211; The vertical base has a flange and is installed with the D end facing downward;<\/p>\n<p>V16 &#8211; The vertical base has a flange and is installed with the D end facing up;<\/p>\n<p>The above codes are only for the installation methods of motors and basic components, and other codes are used for the connection methods with equipment.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>The way an electric motor is mounted (see diagram below) refers to how it is connected to the frame or other components in a mechanical system. There are two code forms, one is IMBx and the other is IMVy. Among them, IM is the internationally accepted installation method code; B represents horizontal type, which is &hellip; <a href=\"http:\/\/gn-desander-desilter.com\/index.php\/2024\/03\/06\/brief-introduction-to-motor-mounting-type\/\" class=\"more-link\">Continue reading<span class=\"screen-reader-text\"> &#8220;Brief introduction to motor mounting type&#8221;<\/span><\/a><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[],"tags":[],"class_list":["post-525","post","type-post","status-publish","format-standard","hentry"],"_links":{"self":[{"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/posts\/525","targetHints":{"allow":["GET"]}}],"collection":[{"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/comments?post=525"}],"version-history":[{"count":1,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/posts\/525\/revisions"}],"predecessor-version":[{"id":526,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/posts\/525\/revisions\/526"}],"wp:attachment":[{"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/media?parent=525"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/categories?post=525"},{"taxonomy":"post_tag","embeddable":true,"href":"http:\/\/gn-desander-desilter.com\/index.php\/wp-json\/wp\/v2\/tags?post=525"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}